Parameters Detected

  • Chemistry Measurements: 11 , 12, 14 parameters available

  • Microscopy Measurements: RBC, WBC, Epithelial Cells, Crystal, Casts, Mucus, Yeast , Bacteria, etc. Further sub-classification is available  with  manual on-screen verification

  • RBC Morphological Analysis: automatic analysis and generated with diagrams and images

  • Physical Measurements: color, turbidity, specific gravity and conductivity.

  • Extensional Measurement: pleuroperitoneal fluid , cerebrospinal fluid, gastric fluid , etc

Work Principle

  • Physical measurement: color, turbidity measured by RGB sensor; specific gravity measured by refractometer; conductivity measured by electrode method

  • Chemistry measurement: colorimetry

  • Microscopy measurement: Machine Vision Technology (Automated Morphological Microscopy)

Product Features

Advantages:

  • Unique design with both Chemistry and Microscopy measurements integrated, which makes both measurements done by sampling once

  • Measurement Modes Optional: chemistry, microscopy, or chemistry+microscopy 

 

Physical Measurement:

  • Independent PMC module automatically measures color, turbidity, specific gravity and conductivity.

  • More accurate SG result measured by refractometer

 

Chemistry Measurement:

  • Patent strip feeding device

  • Innovative sample sprinkling technology to avoid undetecllon

  • Test results traceable with image.

​

Microscopy Measurement:

  • Made strictly according to ISLH Recommended Reference Procedure for the Enumeration of Particles in Urine

  • Uncentrifuged urine sample at cutoff concentration level of 3-5 cell/ul are detectable

  • precise morphological analysis of RBC helps to determine the source of heπ1atuna

  • Standardized and confirmatory report with both images and diagrams available. Pop ups indicate on-screen verification with no need to redo the measurement

  • Self-learning function continuously improves the recognition accuracy.

  • Un-centrifuged urine microscopy reference values available

  • CFDA approved quality controls of four levels available

Technical Parameters

  • Throughput:  Chemistry     Microscopy      Chem+M1cro
                                  240T /H        120T /H          120T /H

  • Min. sample volume: 5ml, 3ml intake for chemistry measurement and 0.5ml for microscopy measurement

  • Sample preparation: native sample

  • Built-in barcode reading: Yes

  • Counting Chamber: 3 channel

  • Detection rate: ≥98% for sample at concentration of 5 cells/ul

  • Accuracy: For chemistry measurement, comparing to reference solution, results are within tolerance of one level or no false positive and negative; for microscopy measurement, ≥95%

  •  Repeatability: For chemistry measurement , CV≤ 1%; for microscopy measurement, CV ≤7%

  •  Carryover: At concentration of 4600-5400 cells/ul≤ 1cell/ul,At concentration of 9200-10800 cells/ul≤2cells/ul

  • Verification: Full-view field images + segmented images

  • Report: comprehensive results with images and diagrams

  • Sampler: loading capacity of 60 samples

  • Strip tank capacity: 200 strips

  • STAT: available

  • Data interface: bidirectional

  • LIS/HIS connection: available

  • Results storage: ;;. 200,000 results

  • Dimensions: 825×650×545mm' Weight: 73kg