F810
Automatic Hematology Analyzer
Instrument Introduction
Detection Technology
Nucleic Acid Fluorescence Staining & Flow Cytometry to count WBC. NRBC and 6-part impedence method and flow cytometry for RBC/PLT
Detection mode
CBC, DIFF, NRBC, RET, SR
Sample mode
Whole Blood Mode, Low Value Leukocyte Mode, Predilution Mode, and Sample Research Mode
Sample volume
Whole blood mode: 88ul
Predilution mode: 70ul
Throughput
CBC+DIFF: 100T/H
CBC+DIFF+RET: 83T/H
Reporting parameters (36 in total)
Leukocyte:
WBC, NEUT(#,%), LYMPH(#,%), MONO(#,%), EO(#,%), BASO(#,%), IG(#,%)
Erythrocyte:
RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, NRBC(#,%)
Platelets:
PLT, PDW, MPV, P-LCR, P-LCC, PCT
Reticulocytes:
RET(#,%), IRF, LFR, MFR, HER, RET-He
Auto loader
Up to 50 sample positions
Linear range
WBC: 0-500x10^9/L
RBC: 0-8.60x10^12/L
HGB: 0-260g/L
PLT: 0-5000x10^9/L
Precision
Parameter Detection Range Precision/%
WBC ≥ 3.50 × 10⁹ /L ≤2.5
RBC ≥ 3.50 × 10¹²/L ≤2.5
HGB 110 g/L – 180 g/L ≤1.0
PLT ≥ 100 × 10⁹ /L ≤4.0
HCT or MCV 30% – 50% (HCT) or 80 fL – 100 fL (MCV) ≤ 1.5 (HCT)
Principal
Special fluorescent staining solution will dye DNA or RNA blandly while 2nd Generation chemistry staining reagents will dye Enzymes/particles in cytoplasm. We know that different cells have different concentrations of DNA or RNA, which causes the depth of dying to be different. The more DNA or RNA, the stronger fluorescence signal. Since nucleic acid is the most specific part of the cell, the 3rd Generation is more sensitive to distinguish different leukocytes, especially the abnormal cells.
Combine 3rd Generation technology with flow cytometry. A single-cell stream quickly passes through a channel in the middle, and every passing cell is detected by three beams of light from three directions to get size, granularity, and nucleic acid information.
FSL (Forward Scattered Light) mainly reflects the size of the cells.
SSC (Side Scattered Light) mainly reflects the size and number of particles in cells.
SFL (Side Fluorescence Light) mainly reflects the concentration of nucleic acid.
Multiple Channels
In FCW channel, WBC, Baso, and NRBCs results will be provided. Baso and NRBCs are generated without extra reagent or cost
In FCD channel, F810 analyzer not only gives WBC 6-part differential results (with immature granulocyte),but also brings 29
research parameters
In FCR channel, 6 reticulocyte results and PLT counting (PLT-O) will be provided. PLT-O can improve the accuracy of low platelet
counting
The flow cytometry technology was used on RBC/PLT chamber which not only make more accurate RBC/PLT results but also ensure very low clog rate
LW Mode (Low White Blood Cell)
Resampling, changing channels, increasing the count by 3 times
The increase of counting particles not only makes the detection of low value have better precision, but also enables the classification of white blood cells in low value samples and the sensitive capture of juvenile cells in them, so as to avoid unnecessary risks
SR mode
Besides blood specimen, F880 also has body fluid test function without requiring dedicated reagent. The various types of body fluids include Peritoneal fluid, Pleural fluid, Cerebrospinal fluid(CSF) and Synovial fluid
Test Options
Sample: WB、Capillary blood、Pre-dilute blood、Body fluid
Efficient
Up to100T/H(CBC+DIFF)
Up to 83T/H(CBC+RET)
Up to 83T/H(CBC+DIFF+RET)
Up to 17T/H(SR)
Visual reagent management
Built-in reagent position for dye
Special loading design: Better separation and much safer
Auto loader
50 position
Built-in barcode for sample tube
Automatically rotate and adjust the barcode position for identification
Automatic rerun and reflect
Return the sample racks for an automatic rerun or reflex check.
Comparative analysis of multiple outcomes in the same patient
Easy-to-use software
User-defined interface
Intuitive interface